Proper UPS selection for servers with active PFC power supplies

Number: AN -147 V2Type: PDFSize: 90 KBThis document explains why some Back-UPS or Smart-UPS SC models may not be the proper choice for servers and other equipment that use large PFC (power factor...

View Article


Electrolyte Quantities in InfraStruxure UPSs

Number: AN -143 V2Type: PDFSize: 67 KBThis document gives the specifications for how much electrolyte is in the valve-regulated lead-acid (VRLA) modular battery cartridges of InfraStruxure UPSs for...

View Article


Smart-UPS configuration application note

Number: AN -80 V0Type: PDFSize: 1417 KBSmart-UPS and Smart-UPS XL behavior can be flexibly adjusted to the actual operating condition through an extended set of user-configurable parameters. Proper...

View Article

Configuring Data Centers to Support IBM BladeCenter Servers

Number: AN -76 V2Type: PDFSize: 186 KBThe IBM BladeCenter operates at a power density 10X greater than the capability of a typical data center, which demands special attention to the power and cooling...

View Article

Configuring Data Centers to Support HP BladeSystem p-Class Servers

Number: AN -75 V1Type: PDFSize: 1046 KBHP BladeSystem p-Class servers operate at a power density 10X higher than that of a typical data center, which demands special attention to the power and cooling...

View Article


Smart-UPS Communications

Number: AN -181 V2Type: PDFSize: 196 KBThis document outlines the various connection options available in the Smart-UPS products to communicate with your PC or server

View Article

Software interface for Switched Outlet and UPS Management in Smart-UPS

Number: AN -177 V1Type: PDFSize: 298 KBThis App Note explains how to manage the behaviour of the Smart-UPS and its outlets through a custom application making use of standard Modbus communications.

View Article

Hot Aisle Containment Application Guidelines and Approved Configurations

Number: AN -146 V1Type: PDFSize: 259 KBThe Hot Aisle Containment System (HACS) is a modular ceiling panel and door system for use in isolating the supply and return air between an APC NetShelter rack...

View Article


Selection procedure for RC and RP

Number: AN -126 V0Type: PDFSize: 81 KBDescribes the procedure for selecting InRow Chilled Water products for successful applications.

View Article


Rack Air Containment Application Guidelines and Approved Configurations

Number: AN -90 V3Type: PDFSize: 172 KBThe Rack Air Containment System (RACS) is a modular front and rear plenum for use in isolating the supply and return air between an APC Netshelter SX rack...

View Article

PowerChute Network Shutdown for Nutanix Clusters (AHV, ESXi)

Number: AN -197 V1Type: PDFSize: 652 KBThis Application Note provides step-by-step instructions to ensure the safe shutdown of a Nutanix Cluster using APC PowerChute Network Shutdown.

View Article

Hot Aisle Containment System (HACS) and Data Center Fire Protection

Number: AN -159 V0Type: PDFSize: 184 KBThe design of data centers around Hot Aisle Containment Systems (HACS) is growing in popularity. Engineers and, increasingly, Authorities Having Jurisdiction...

View Article

StruxureWare Data Center Expert v7.2 Building Management System Integration

Number: AN -156 V3Type: PDFSize: 503 KBProvide a technical description of how InfraStruXure Central can integrate into a higher level building management system through the ModBus TCP protocol

View Article


RDX Remote Fluid Cooled Condenser InRow DX 600mm

Number: AN -141 V1Type: PDFSize: 327 KBThe InRow DX 600mm Series of InRow DX cooling products has been designed for use with remote air-cooled condensers, and is supported by a variety of condenser...

View Article

Cable Trough, Ladder, and Partition Configuration Guide

Number: AN -133 V1Type: PDFSize: 815 KBManagement of power and data cabling is critical for data center installation and long-term maintenance. APC has developed a line of products designed to contain...

View Article


TUV - Rheinland NRTL Certification

Number: AN -131 V0Type: PDFSize: 166 KBThis paper describes use of the TUV-Rheinland NRTL mark in lieu of the UL and C-UL (or CSA) marks for the North American Market (NAM). This paper is limited in...

View Article

Best Practices for Designing Data Centers with the InRow RC

Number: AN -92 V0Type: PDFSize: 1188 KBThe InfraStruXure InRow RC is designed to provide cooling at the row and rack level of a data center for rack based IT equipment with front to back airflow. When...

View Article


Rack Air Distribution Unit

Number: AN -69 V1Type: PDFSize: 135 KBDetailed description how to apply the various uses of the Rack Air Distribution Unit into a datacenter or IT space.

View Article

PowerChute Business Edition Security Features and Recommendations

Number: AN -199 V0Type: PDFSize: 94 KBThis Application Note provides an overview of the security features in PowerChute Business Edition and recommendations on how to securely deploy the software

View Article

Symmetra PX 20kW UPS Installation Deviation and Selection of Input Circuit...

Number: AN -150 V1Type: PDFSize: 251 KBThe Symmetra PX 20kW UPS system provides customers with unique UPS power level scalability. This document gives the specifications for permitted input circuit...

View Article