Selection Process for Dew Point Control Pump (ACRC301H)
Number: AN -184 V0Type: PDFSize: 499 KBThe Dew Point Control Pump [DPCP] is a condensate management device used in the InRow RC High Temp cooling unit. It serves as an alternative to the traditional...
View ArticleNeutral arrangements for the MGE Galaxy 5000, MGE Galaxy 5500 and MGE Galaxy...
Number: AN -172 V2Type: PDFSize: 1383 KBThis document has been written in order to have as complete list describing every neutral arrangement dedicated to Galaxy 5000 and Galaxy 7000, including their...
View ArticleUsing PowerChute Network Shutdown in Parallel Redundant or Parallel Capacity...
Number: AN -169 V0Type: PDFSize: 174 KBThis Application Note provides an overview of Parallel-UPS configurations and explains the PowerChute Network Shutdown event handling process for UPSs in these...
View ArticleIntegrating Digi Wireless Environmental Monitoring with NetBotz Appliances in...
Number: AN -164 V0Type: PDFSize: 61 KBDetails the extension of NetBotz using Digi wireless sensors.
View ArticleSymmetra PX 20kW UPS Installation Deviation and Selection of Input Circuit...
Number: AN -150 V1Type: PDFSize: 251 KBThe Symmetra PX 20kW UPS system provides customers with unique UPS power level scalability. This document gives the specifications for permitted input circuit...
View ArticleElectrolyte Quantities in InfraStruxure UPSs
Number: AN -143 V2Type: PDFSize: 67 KBThis document gives the specifications for how much electrolyte is in the valve-regulated lead-acid (VRLA) modular battery cartridges of InfraStruxure UPSs for...
View ArticleCable Trough, Ladder, and Partition Configuration Guide
Number: AN -133 V1Type: PDFSize: 815 KBManagement of power and data cabling is critical for data center installation and long-term maintenance. APC has developed a line of products designed to contain...
View ArticleInRow RC Cooling of HP C-Class Chassis
Number: AN -132 V0Type: PDFSize: 144 KBHigh performance blade chassis such as the HP c-Class are alleged to be highly problematic regarding thermal solutions within traditional Data Center spaces. APC...
View ArticleSelection procedure for RC and RP
Number: AN -126 V0Type: PDFSize: 81 KBDescribes the procedure for selecting InRow Chilled Water products for successful applications.
View ArticleUsing MCA and MOP Ratings to Safely Connect Your Field Wired Air Conditioner
Number: AN -121 V0Type: PDFSize: 94 KBThe minimum circuit ampacity (MCA) and maximum overcurrent protection (MOP) ratings provide guidance for safely connecting field-wired equipment to the building...
View ArticleACRP Requirements for Selecting 3rd Party Remote Air-Cooled Condenser and...
Number: AN -120 V0Type: PDFSize: 335 KBThe InfraStruXure InRow RP (ACRP100, ACRP101, and ACRP102) is an air-cooled DX air conditioner for data centers. All air-cooled air conditioners require the use...
View ArticleUPS Power for the InfraStruXure InRow SC
Number: AN -115 V0Type: PDFSize: 55 KBThe InfraStruXure InRowT SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets. This application note outlines...
View ArticleConfiguration Types and Sequence of Operations for the InfraStruXure InRow SC
Number: AN -113 V0Type: PDFSize: 140 KBThe InfraStruXure InRowT SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets. This application note outlines various...
View ArticleBest Practices for Deploying the InfraStruXure InRow SC
Number: AN -112 V0Type: PDFSize: 233 KBThe InfraStruXure InRowT SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets. This application note outlines best...
View ArticleApplication Guidelines for the InfraStruXure InRow SC Condenser
Number: AN -109 V0Type: PDFSize: 223 KBThe InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets. This application note outlines various...
View ArticleAlternative Network Connectivity Options for APC NetBotz Monitoring Appliances
Number: AN -91 V1Type: PDFSize: 161 KBAPC NetBotz monitoring appliances come standard with a 10/100 Ethernet port. This is the predominant connection for most customers, however for some locations...
View ArticleConfiguring Data Centers to Support IBM BladeCenter Servers
Number: AN -76 V2Type: PDFSize: 186 KBThe IBM BladeCenter operates at a power density 10X greater than the capability of a typical data center, which demands special attention to the power and cooling...
View ArticleConfiguring Data Centers to Support HP BladeSystem p-Class Servers
Number: AN -75 V1Type: PDFSize: 1046 KBHP BladeSystem p-Class servers operate at a power density 10X higher than that of a typical data center, which demands special attention to the power and cooling...
View ArticleRack Air Distribution Unit
Number: AN -69 V1Type: PDFSize: 135 KBDetailed description how to apply the various uses of the Rack Air Distribution Unit into a datacenter or IT space.
View ArticleAPC Network Management Card Security Implementation
Number: AN -67 V3Type: PDFSize: 439 KBThis document highlights the industry-standard security implementation on the Network Management Card from Schneider Electric and should be used as a high-level...
View Article